Hydraulic Valves
87
IH-TDB-001-C/EN wrc_2015-02-03 IH-TDB-001-C/EN wrc_2015-02-03
Pilot Operated Proportional DC Valves
with position feedback
2.6
Characteristic Curves / Pilot Flow HP**VW
3-62
D_1FC UK.indd RH 05.05.2014
Pilot Operated Proportional DC Valve
Series D*1FC
3
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
Technical Data / Characteristic Curves
Electrical characteristics
Duty ratio [%] 100
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Supply voltage/ripple DC [V] 18...30, ripple < 5 % eff., surge free
Current consumption max. [A] 2.0
Pre fusing medium lag [A] 2.5
Command signal
Code K (B) Voltage
Impedance
Code E Current
Impedance
Code S Current
[V]
[kOhm]
[mA]
[Ohm]
[mA]
10...0...-10, ripple <0.01 % eff., surge free, 0...+10 V P—>A (P—>B)
100
20...0...-20, ripple <0.01 % eff., surge free, 0...+20 mA P—>B
200
4...12...20, ripple <0.01 % eff., surge free, 12...20 mA P—>A
< 3.6 mA = enable off, > 3.8 mA = enable on acc. to NAMUR NE43
Impedance [Ohm] 200
Differential input max. Code 0/7
Code 0
[V]
[V]
30 for terminal D and E against PE (terminal G)
11 for terminal D and E against 0 V (terminal B)
Adjustment ranges Min [%] 0...50
Max [%] 50...100
Ramp [s] 0...32.5
Interface RS 232, parametrizing connection 5pole
EMC EN 61000-6-2, EN 61000-6-4
Electrical connection 6 + PE acc. to EN 175201-804
Wiring min. [mm²] 7 x 1.0 (AWG16) overall braid shield
Wiring length max. [m] 50
All characteristic curves measured with HLP46 at 50 °C.
Electrical characteristics hybrid option
Duty ratio [%] 100
Protection class IP 65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Supply voltage [V] 24
Tolernace supply voltage [%] ±10
Current consumption [A] 1.21
Power consumption [W] 29
Solenoid connection Connector as per EN 175301-803
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
P-B
A-T
P-A
B-T
Command signal [%]
-80
100
[% of nominal flow]Flow Q
-60 -40 -20 020406080 100-100
75
50
25
0
50%
(B*)
B-TP-B
P-A
B-T
P-B
A-T
Command signal [%]
-80
100
[% of nominal flow]Flow Q
-60 -40 -20 020406080 100-100
75
50
25
0
50%
(B*)
B-TP-B
Spool code E01, E02, B31, B32
D*1FC B/E Flow characteristics
at Dp = 5 bar per metering edge
D31FC
Spool code E01, E02, B31, B32
3-63
D_1FC UK.indd RH 05.05.2014
Pilot Operated Proportional DC Valve
Series D*1FC
3
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
Characteristic Curves
D111FC
Spool type E01, E02, B31, B32
D91FC
Spool type E01, E02, B31, B32
P-A
B-T
P-B
A-T
Command signal [%]
-80
100
[% of nominal flow]Flow Q
-60 -40 -20 020406080 100-100
75
50
25
50%
(B*)
B-TP-B
Command signal [%]
-80
100
[% of nominal flow]Flow Q
P-A
B-T
P-B
A-T
-60 -40 -20 020406080 100-100
75
50
25
0
50%
(B*)
B-TP-B
D111FC
spool type R/Z* on request
Flow curves D*1FCR/Z
at Dp = 5 bar per metering edge
D31FC
Spool type R31, R32
D91FC
Spool type R31, R32, Z31, Z32
D41FC
Spool type R31, R32, Z31, Z32
P-B
A-T
P-A
B-T
1)
1)
with 2 tank ports
-100
75
50
25
0
-80 -60 -40
-20
0
20 40 60 80 100
50%
(R* )
Command signal [%]
Flow [% of nominal flow]Q
All characteristic curves measured with HLP46 at 50 °C.
HP10VW HP16VW
HP25VW HP32VW
Q/2
Q/2 Q/2
Q/2
3-66
D_1FC UK.indd RH 05.05.2014
Pilot Operated Proportional DC Valve
Series D*1FC
3
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
Pilot Flow
1/16"NPTF
1/16"NPTF
X
B
C
Y
T
()drawn offset
P
M6 DIN906
1/16 NPTF
T
C
B
P
B
C 1/16"NPTF
1/16"NPTF
X
()drawn offset
open, closed
Pilot oil
Inlet
Drain
internal
external
internal
external
external
external
internal
internal
D31FCB/E D31FCR
D41FCB/E D41FCR D41FCZ
D91FCB/E D91FCR D91FCZ
D111FCB/E D111FCR D111FCZ
P
xy
T
B
C
a
b
0
B
A
)( )(
Pilot oil inlet (supply) and outlet (drain)
D_1FC DE.indd RH 05.05.2014
3-44
Vorgesteuertes Proportional-Wegeventil
Serie D*1FC
3
Katalog HY11-3500/DE
Parker Hannifin Corporation
Hydraulics Group
Steuerölführung
1/16"NPTF
1/16"NPTF
X
B
C
Y
T
()versetzt gezeichnet
P
M6 DIN906
1/16 NPTF
T
C
B
P
B
C 1/16"NPTF
1/16"NPTF
X
()versetzt gezeichnet
intern
extern
intern
extern
extern
extern
intern
intern
offen, geschlossen
Steueröl
Zulauf
Ablauf
D31FCB/E
D31FCR
D41FCB/E D41FCR D41FCZ
D91FCB/E D91FCR D91FCZ
D111FCB/E D111FCR D111FCZ
P
xy
Steuerölführung Eingang (Zulauf) und Ausgang (Ablauf)
D_1FC DE.indd RH 05.05.2014
3-44
Vorgesteuertes Proportional-Wegeventil
Serie D*1FC
3
Katalog HY11-3500/DE
Parker Hannifin Corporation
Hydraulics Group
Steuerölführung
1/16"NPTF
1/16"NPTF
X
B
C
Y
T
()versetzt gezeichnet
P
M6 DIN906
1/16 NPTF
C
B
P
B
C 1/16"NPTF
1/16"NPTF
X
()versetzt gezeichnet
intern
extern
intern
extern
extern
extern
intern
intern
offen, geschlossen
Steueröl
Zulauf
Ablauf
D41FCB/E
D41FCR D41FCZ
D91FCB/E D91FCR D91FCZ
D111FCB/E D111FCR D111FCZ
P
xy
Steuerölführung Eingang (Zulauf) und Ausgang (Ablauf)
D_1FC DE.indd RH 05.05.2014
3-44
Vorgesteuertes Proportional-Wegeventil
Serie D*1FC
3
Katalog HY11-3500/DE
Parker Hannifin Corporation
Hydraulics Group
Steuerölführung
1/16"NPTF
1/16"NPTF
X
B
C
Y
T
()versetzt gezeichnet
P
M6 DIN906
1/16 NPTF
T
C
B
P
B
C 1/16"NPTF
1/16"NPTF
X
()versetzt gezeichnet
intern
extern
intern
extern
extern
extern
intern
intern
offen, geschlossen
Steueröl
Zulauf
Ablauf
D31FCB/E D31FCR
D41FCB/E D41FCR D41FCZ
D91FCB/E
D91FCR D91FCZ
D111FCB/E D111FCR D111FCZ
P
xy
Steuerölführung Eingang (Zulauf) und Ausgang (Ablauf)
D_1FC DE.indd RH 05.05.2014
3-44
Vorgesteuertes Proportional-Wegeventil
Serie D*1FC
3
Katalog HY11-3500/DE
Parker Hannifin Corporation
Hydraulics Group
Steuerölführung
1/16"NPTF
1/16"NPTF
X
B
C
Y
T
()versetzt gezeichnet
P
M6 DIN906
1/16 NPTF
T
C
B
P
B
C 1/16"NPTF
1/16"NPTF
X
()versetzt gezeichnet
intern
extern
intern
extern
extern
extern
intern
intern
offen, geschlossen
Steueröl
Zulauf
Ablauf
D31FCB/E D31FCR
D41FCB/E D41FCR D41FCZ
D91FCB/E D91FCR D91FCZ
D111FCB/E D111FCR D111FCZ
P
xy
Steuerölführung Eingang (Zulauf) und Ausgang (Ablauf)
HP10VW
HP16VW HP25VW
HP32VW